12,436 research outputs found

    High Speed Peltier Calorimeter for the Calibration of High Bandwidth Power Measurement Equipment

    Full text link
    Accurate power measurements of electronic components operating at high frequencies are vital in determining where power losses occur in a system such as a power converter. Such power measurements must be carried out with equipment that can accurately measure real power at high frequency. We present the design of a high speed calorimeter to address this requirement, capable of reaching a steady state in less than 10 minutes. The system uses Peltier thermoelectric coolers to remove heat generated in a load resistance, and was calibrated against known real power measurements using an artificial neural network. A dead zone controller was used to achieve stable power measurements. The calibration was validated and shown to have an absolute accuracy of +/-8 mW (95% confidence interval) for measurements of real power from 0.1 to 5 W

    Numerical solutions of atmospheric flow over semielliptical simulated hills

    Get PDF
    Atmospheric motion over obstacles on plane surfaces to compute simulated wind fields over terrain features was studied. Semielliptical, two dimensional geometry and numerical simulation of flow over rectangular geometries is also discussed. The partial differential equations for the vorticity, stream function, turbulence kinetic energy, and turbulence length scale were solved by a finite difference technique. The mechanism of flow separation induced by a semiellipse is the same as flow over a gradually sloping surface for which the flow separation is caused by the interaction between the viscous force, the pressure force, and the turbulence level. For flow over bluff bodies, a downstream recirculation bubble is created which increases the aspect ratio and/or the turbulence level results in flow reattachment close behind the obstacle

    Cosmic soft gamma-ray bursts and the stellar super-flare hypothesis

    Get PDF
    Cosmic soft gamma ray bursts are discussed, and the stellar super-flare hypothesis is supported. Previous predictions and observations of gamma ray bursts are cited. Studies show that it is plausible that the bursts are caused by the bremsstrahlung of electrons accelerated to high energies in a stellar flare event. Possible observational consequences are listed for the stellar flare hypothesis

    A comparison of three canopy interception models for a leafless mixed deciduous forest stand in the eastern United States

    Get PDF
    Canopy interception of incident precipitation is a critical component of the forest water balance during each of the four seasons. Models have been developed to predict precipitation interception from standard meteorological variables because of acknowledged difficulty in extrapolating direct measurements of interception loss from forest to forest. No known study has compared and validated canopy interception models for a leafless deciduous forest stand in the eastern United States. Interception measurements from an experimental plot in a leafless deciduous forest in northeastern Maryland (39°42'N, 75°5'W) for 11 rainstorms in winter and early spring 2004/05 were compared to predictions from three models. The Mulder model maintains a moist canopy between storms. The Gash model requires few input variables and is formulated for a sparse canopy. The WiMo model optimizes the canopy storage capacity for the maximum wind speed during each storm. All models showed marked underestimates and overestimates for individual storms when the measured ratio of interception to gross precipitation was far more or less, respectively, than the specified fraction of canopy cover. The models predicted the percentage of total gross precipitation (PG) intercepted to within the probable standard error (8.1%) of the measured value: the Mulder model overestimated the measured value by 0.1% of PG; the WiMo model underestimated by 0.6% of PG; and the Gash model underestimated by 1.1% of PG. The WiMo model’s advantage over the Gash model indicates that the canopy storage capacity increases logarithmically with the maximum wind speed. This study has demonstrated that dormant-season precipitation interception in a leafless deciduous forest may be satisfactorily predicted by existing canopy interception models

    Design of prototype charged particle fog dispersal unit

    Get PDF
    The unit was designed to be easily modified so that certain features that influence the output current and particle size distribution could be examined. An experimental program was designed to measure the performance of the unit. The program described includes measurements in a fog chamber and in the field. Features of the nozzle and estimated nozzle characteristics are presented

    Charged particle concepts for fog dispersion

    Get PDF
    Charged particle techniques hold promise for dispersing warm fog in the terminal area of commercial airports. This report focuses on features of the charged particle technique which require further study. The basic physical principles of the technique and the major verification experiments carried out in the past are described. The fundamentals of the nozzle operation are given. The nozzle characteristics and the theory of particle charging in the nozzle are discussed, including information from extensive literature on electrostatic precipitation relative to environmental pollution control and a description of some preliminary reported analyses on the jet characteristics and interaction with neighboring jets. The equation governing the transfer of water substances and of electrical charge is given together with a brief description of several semi-empirical, mathematical expressions necessary for the governing equations. The necessary ingredients of a field experiment to verify the system once a prototype is built are described

    Neutrally stable atmospheric flow over a two-dimensional rectangular block

    Get PDF
    The phenomena of atmospheric flow over a two dimensional surface obstruction such as a building modeled as a rectangular block are analyzed by an approach using the Navier-Stokes equations with a two equation model of turbulence. The partial differential equations for the vorticity, stream function, turbulence kinetic energy, and turbulence length scale are solved by a finite difference technique. The predicted results are in agreement with the limited experimental data available. Current computed results show that the separation bubble originates from the upper front corner of the block and extends approximately 11.5 block heights behind the block. The decay of the mean velocity along the wake center line coincides almost perfectly with the experimental data. The vertical profiles of the mean velocity defect are also in reasonable agreement with wind tunnel results. Velocity profiles in the mixing region are shown to agree with the error function profile typically found in the shear layer. Details of the behavior of the turbulence kinetic energy and the turbulence length scale are also discussed
    • …
    corecore